hongce@iectester.comAEEDL-006 is based on the air enthalpy difference method and constructs an "indoor + outdoor dual-chamber" test system, covering an ultra-wide temperature range of -20~60℃ and an air volume of 200-2000CFM. It is compatible with environmentally friendly refrigerants such as R32/R290, complies with GB 7725-2010 and ISO 5151/13253 standards, and accurately measures core performance of air conditioning such as cooling/heating, defrosting, and energy efficiency (COP/SEER).
رقم الصنف :
HONGCEالنظام (موك) :
AEEDL-006دفع :
Calibration certificate(cost additional)أصل المنتج :
ChinaPayment Method :
L/C, T/TRegular Packaging :
PlywoodAir Conditioning Enthalpy Difference Test Room Multi-Refrigerant Air Conditioning Performance Test System
Product Introduction
AEEDL-006 consists of an indoor test chamber, an outdoor simulation chamber, an air handling unit, and an intelligent measurement and control system:
Product Features
International reference standards
Product use
Technical Parameters
Item | Technical Details |
Model | AEEDL-006 |
Test Method | Air Enthalpy Difference Method |
Chamber Layout | 1 Indoor Chamber + 1 Outdoor Chamber |
Indoor Temp. Range | 10–50℃ |
Outdoor Temp. Range | -20–60℃ |
Relative Humidity | 35–90%RH (Indoor/Outdoor) |
Airflow Range (CFM) | 200–2000 (Airflow Measurement Chamber) |
Indoor Static Pressure | -50–500Pa |
Thermocouple Channels | 20 (Indoor/Outdoor, -50~150℃) |
Refrigerant Pressure Ports | 2 (Outdoor Side) |
Power Meter | WT333E (1 Channel, ±0.2% Precision) |
Variable Frequency Power | 3-Phase, 45kVA |
Supported Refrigerants | R22, R410a, R32, R290, R134a |
Compliance Standards | GB 7725-2010, ISO 5151-2017, ISO 13253-2017 |
Test Items | Rated Cooling/Heating, Max/Min Performance, Defrost, Freezing, Condensate Control, COP/SEER |