enen/ arar
وطن Wall-mounted boiler testing equipment

Gas Wall-Mounted Boiler Comprehensive Performance Testing Equipment Compatible With Multiple National Standards

Gas Wall-Mounted Boiler Comprehensive Performance Testing Equipment Compatible With Multiple National Standards

WMB-002 is the core equipment for full performance testing of gas wall-mounted boilers. It is deeply compatible with 8 national standards such as GB6932-2015, GB25034-2010, CJ/T395-2012, and can simultaneously complete full-dimensional tests of heat load, energy efficiency, water/gas parameters, wind pressure and electricity (with an accuracy of 0.5% F.S), covering the research and development verification, production line quality inspection and inspection and certification scenarios of water heaters, heating furnaces, and condensing models.

  • رقم الصنف :

    HONGCE
  • النظام (موك) :

    WMB-002
  • أصل المنتج :

    CHINA
  • Payment Method :

    L/C, T/T
  • Regular Packaging :

    Plywood

Gas Wall-Mounted Boiler Comprehensive Performance Testing Equipment Compatible With Multiple National Standards

 

Product introduction:

  • Seamless coverage of multiple national standards: Integrated hot water (GB6932), heating (GB25034), condensing (CJ/T395) and other 8 national standard test logics, set automatically to adapt to the standard once.
  • Synchronous detection of all parameters: Synchronous acquisition of 20+ parameters such as water flow (0-40L/min), gas pressure (0-10kPa), wind pressure (0-1000Pa), etc., and detection efficiency is increased by 60% (compared with split equipment).
  • 0.5% F.S high precision: Water/gas parameter accuracy reaches 0.5% F.S, gas humidity 0.1% F.S, captures micro deviations (such as 0.1kPa gas pressure fluctuations), and supports accurate determination of energy efficiency levels.

 

National reference standards:

  • GB6932-2015 Hot water performance test: rated heat load, 50% heat load, water temperature fluctuation.
  • GB25034-2010 Heating performance test: rated heat load, 30% heat load.
  • CJ/T395-2012 Condensing model test Condensing heat recovery efficiency, low temperature condition adaptation.
  • GB26655-2015 Energy efficiency grade determination: thermal efficiency, energy consumption limit value.
  • CJ/T336-2010 Condensing instantaneous water heater test: thermal output stability, flue gas emission.

 

Product use:

  • R&D verification: The company's laboratory tests the thermal efficiency and water/gas parameter matching of new products (such as low-temperature conditions for condensing models).
  • Production line quality inspection: Final inspection of the whole wall-mounted boiler factory (heat load, energy efficiency, water/gas parameter compliance, 30+ units tested per day).
  • Inspection and certification: A third-party testing agency issues a test report with the CNAS logo (data is directly used for market access).

 

Technical Parameters

Parameter Technical Details
Model WMB-002
Compliant Standards 8 National Standards (GB6932/GB25034/CJ/T395, etc.)
Hot Water Flow Range 0–30L/min (Sanitary) / 0–40L/min (Heating)
Water Pressure Range 0–1.6MPa (Inlet) / 0–0.6MPa (Circulation)
Water Temperature Range 0–100℃ (Inlet/Outlet/Return)
Gas Pressure Range 0–10kPa (Main) / 0–5kPa (Secondary)
Gas Flow Range 0–5m³/h (Dry: 1% F.S / Wet: 0.5% F.S)
Gas Humidity Range 0–100%RH (0.1% F.S)
Air Pressure Range 0–1000Pa (1% F.S)
Electrical Parameter Range Voltage: 0–300V / Current: 0–4A (1% F.S)
Control Mode PLC + 10-inch Touchscreen HMI
Data Storage ≥5000 Records (USB/Ethernet Export)
Power Supply AC220V±10%/50Hz, 100W
Ambient Temperature 0–40℃ (Non-condensing)
Relative Humidity ≤80% RH
Protection Rating IP30 (Cabinet) / IP40 (Sensor)
Dimensions (L×W×H) 800×600×1200mm (Cabinet)
Equipment Weight 65kg (Main Unit)

 

اترك رسالة
إذا كنت مهتمًا بمعداتنا وتريد معرفة المزيد من التفاصيل، فيرجى ترك رسالة هنا.سوف نتصل بك في أقرب وقت ممكن.

منتجات ذات صله

Close-up of the electric wall-mounted boiler performance test bench
Source manufacturer Electric wall-mounted boiler performance test bench Accurate detection Supports multiple model testing

This equipment is specially designed for testing the performance of electric wall-mounted boilers. It is committed to providing customers with comprehensive solutions, strictly controlling product quality, improving product competitiveness, and accelerating product research and development.

التفاصيل
Overall appearance of wall-mounted boiler durability test equipment
Multi-station wall-mounted boiler durability test equipment ±0.5℃ high-precision temperature control

In the quality control of wall-mounted boilers, the wall-mounted boiler durability testing equipment can help you solve the problem of wall-mounted boiler quality inspection with its accurate testing data and humanized design.

التفاصيل
Left view of the comprehensive test bench for wall-mounted boiler parts
High-precision intelligent wall-mounted boiler parts comprehensive test bench Direct supply from the source manufacturer

With humanized design and excellent performance, we provide comprehensive and high-precision solutions for the inspection of wall-mounted boiler parts, helping enterprises to control quality and improve market competitiveness.

التفاصيل
Wall-mounted Boiler Testing Equipment
GB6932 Gas Wall-Mounted Boiler Combustion Chamber Sealing Performance Test Equipment 0.6-10m³/H Leakage Test

WMB-001 is the core equipment for detecting the combustion chamber seal of gas wall-mounted boilers. It strictly complies with Article 7.16 of GB6932-2001 "National Standard for Household Gas Instantaneous Water Heaters" to accurately detect the leakage of the combustion chamber. Through the 1.5-level precision flow meter and PLC + touch screen intelligent control, it can realize automatic testing and judgment of the leakage of the sealing structure, and is suitable for wall-mounted boiler production quality inspection, R&D and third-party testing scenarios.

التفاصيل
Wall-mounted Boiler Combustion Chamber Tester
Gas Wall-Mounted Boiler Comprehensive Performance Testing Equipment Compatible With Multiple National Standards

WMB-002 is the core equipment for full performance testing of gas wall-mounted boilers. It is deeply compatible with 8 national standards such as GB6932-2015, GB25034-2010, CJ/T395-2012, and can simultaneously complete full-dimensional tests of heat load, energy efficiency, water/gas parameters, wind pressure and electricity (with an accuracy of 0.5% F.S), covering the research and development verification, production line quality inspection and inspection and certification scenarios of water heaters, heating furnaces, and condensing models.

التفاصيل
Wall-mounted Boiler Combustion Chamber Tester
Gas Heating Furnace Aging Test Equipment Gb6932/Gb2665 Compliance

WMB-003 is the core equipment for aging test of gas heating furnaces and water heaters. It strictly complies with GB6932-2015 (domestic gas instantaneous water heaters) and GB26655-2015 (energy efficiency limit values) standards, and simulates real aging conditions through computer + PLC intelligent control (precise control of water / gas pressure, temperature, and flow, with an accuracy of 0.5% F.S).

التفاصيل
Wall-mounted Boiler Combustion Chamber Tester
Wall-Mounted Boiler Durability Test Equipment Multi-Station Plc Intelligent Control Support Customization

HCTE-WMBT002 is the core equipment for life verification of gas heating water boilers. It supports flexible expansion of 1-50 stations, accurately controls water pressure (0.05-0.5MPa), gas pressure (0.5-5kPa) and water on-off time (0-999s), and realizes 999999 cycles of endurance test through PLC + touch screen control. It is suitable for R&D life verification, production line batch testing and quality inspection and certification scenarios. The core components are imported brands to ensure test stability.

التفاصيل
Wall-mounted Boiler Combustion Chamber Tester
Comprehensive Test Bench For Wal Mounted Boiler Parts Multi-Component Integrated Testing

WMBT003 is a full-dimensional test platform for the core components of gas wall-mounted boilers. It integrates four modules: proportional valve air tightness, water flow sensor, burner performance, and pressure resistance test. Through PLC + touch screen intelligent control, it achieves 0.1V voltage resolution and 1-30L/min water flow precision control. It is suitable for wall-mounted boiler R&D verification, production line quality inspection and supplier inspection scenarios. The core valve group adopts imported brands to ensure test stability.

التفاصيل

اترك رسالة

اترك رسالة
إذا كنت مهتمًا بمعداتنا وتريد معرفة المزيد من التفاصيل، فيرجى ترك رسالة هنا.سوف نتصل بك في أقرب وقت ممكن.
إرسال

ساعات العمل لدينا

الإثنين 21/11 - الأربعاء 23/11: 9 صباحًا - 8 مساءً
الخميس 24/11: مغلق - عيد شكر سعيد!
الجمعة 25/11: 8 صباحًا - 10 مساءً
السبت 26/11 - الأحد 27/11: 10 صباحًا - 9 مساءً
(جميع الساعات بالتوقيت الشرقي)

اتصل بنا :hongce@iectester.com

وطن

منتجات

whatsApp

الاتصال