hongce@iectester.comWMB-001 is the core equipment for detecting the combustion chamber seal of gas wall-mounted boilers. It strictly complies with Article 7.16 of GB6932-2001 "National Standard for Household Gas Instantaneous Water Heaters" to accurately detect the leakage of the combustion chamber. Through the 1.5-level precision flow meter and PLC + touch screen intelligent control, it can realize automatic testing and judgment of the leakage of the sealing structure, and is suitable for wall-mounted boiler production quality inspection, R&D and third-party testing scenarios.
رقم الصنف :
HONGCEالنظام (موك) :
WMB-001أصل المنتج :
CHINAPayment Method :
L/C, T/TRegular Packaging :
PlywoodGB6932 Gas Wall-Mounted Boiler Combustion Chamber Sealing Performance Test Equipment 0.6-10m³/H Leakage Test
Product introduction:
International/national reference standards:
Product use:
Technical Parameters
Parameter | Technical Details |
Model No. | WMB-001 |
Test Standard | GB6932-2001, Clause 7.16 |
Leakage Test Range | 0.6–10 m³/h |
Flowmeter Accuracy | Class 1.5 (±1.5% FS) |
Pre-sealing Pressure | 0–200 Pa (Continuously Adjustable) |
Compressed Air Pressure Range | 0.4–0.8 MPa |
Control Mode | PLC + 7-inch HMI (Touch Screen) |
Test Mode | Automatic (Threshold Judgment) / Manual (Step-by-Step) |
Data Storage | ≥1000 Test Records (USB Export Supported) |
Power Supply | AC220V±10%/50Hz, 50W |
Ambient Temperature | 0–40℃ (Non-condensing) |
Relative Humidity | ≤80% RH |
Atmospheric Pressure | 86–106 kPa |
Protection Rating | IP30 (Cabinet) / IP40 (Sensor) |
Dimensions (L×W×H) | 600×400×800 mm (Cabinet) |
Equipment Weight | 35 kg (Main Unit) |